Overview

G150 - Proven power for a variety of larger applications

The G150 mobile generator is a durable, sound attenuated generator that provides mobile, prime power for larger applications requiring quiet reliable power. The T4i models are especially suited for areas requiring BAT (Best Available Technology) to meet the most stringent EPA, CARB air standards. A digital controller monitors and protects the generator and engine while providing continuous operating data on an easy to read LCD display. Large fuel tanks provide long running times.

  • Brushless oversized alternators and separate excitation winding and AVR (Automatic Voltage Regulation) provide superior motor starting and enhanced ability to run non-linear loads.
  • Single switch start and simple uncluttered control panel provide unmatched ease of use.
  • Easy voltage selection using a lockable voltage selector switch reduces connection errors.
  • Standard environmentally friendly "green" features include 115% fluid containment, crankcase oil vapor recovery system, no mess oil and radiator drain hoses/valves and fast fuel fill system (50 gpm).
  • Heavy-duty, tandem-axle trailers with aluminum diamond plate fenders are road ready with DOT lighting, chains, height adjustable coupler, choice of surge or electric brakes.
Specifications
Model
G150
Year
2022
Sale Type
New
Manufacturer
Wacker Neuson
g150 technical specifications

Metric

  G150 (T4F) G150 (T3) - Canada Only G150 (T3) 600V- Canada Only G150 (T4i) - Canada Only

Dimensions 

L x W x H Operating (Skid) mm 2794 x 1143 x 1685 3353 x 1321 x 1727 3353 x 1321 x 1727 3353 x 1321 x 1791
L x W x H Shipping (Skid) mm 2870 x 1207 x1993 3442 x 1384 x 2070 3442 x 1384 x 2070 3442 x 1384 x 2134
L x W x H Shipping/Operating (Trailer) mm 4470 x 2032 x 2332 5055 x 2146 x 2515 5055 x 2146 x 2515 5055 x 2146 x 2553

Weights 

Weight Dry (Skid) kg 2,404 2,813 2,859 2,786
Weight Operating (Skid) kg 2,902 3,765 3,811 3,738
Weight Shipping (Skid) kg 2,488 2,979 3,025 2,952
Weight Operating (Trailer) kg 3,524 4,436 4,482 4,409
Weight Shipping (Trailer) kg 3,025 3,484 3,530 3,457

Operating data 

Trailer coupling Type Pintle Pintle Pintle Pintle
Standby output   kW 130 133 130 133
Prime output  kW 121 121 118 121
Voltage - AC 3 Phase V 240/480 240/480 240/480/600 240/480
Current - 3 Phase (Prime) A 364/182 364/182 355/178/142 364/182
Current - AC 1 Phase A 120/240 120/240 120/240 120/240
Voltage - 3 Phase V 208, 220, 240, 416, 440, 480 Switchable 208, 220, 240, 416, 440, 480 208, 220, 240, 416, 440, 480, 600 208, 220, 240, 416, 440, 480
Voltage - 1 Phase V 120, 127, 139, 240, 254, 277 Adjustable Voltage 120, 127, 139, 240, 254, 277 120, 127, 139, 240, 254, 277, 346 120, 127, 139, 240, 254, 277
Circuit breaker (Main) A 400 400 700 400
Frequency  Hz 60 60 60 60
Power factor 1 Phase cos Φ 1~ 1 1 1 1
Power factor 3 Phase cos Φ 3~ 0.8 0.8 0.8 0.8
Sound level (LwA) at Prime (23 ft / 7 m) dB(A) 73 67.5 67.5 70.4
Receptacles -20 Amp GFI Duplex 2 2 2 2
Receptacles -50 Amp Twist Lock 3 3 3 3

Engine / Motor 

Engine / Motor  Liquid-Cooled, 4 Cylinders Liquid-Cooled, 6 Cylinders Liquid-Cooled, 6 Cylinders Liquid-Cooled, 6 Cylinders
Engine / Motor manufacturer  Cummins QSB5-G12 John Deere John Deere Cummins
Emissions Certified Tier 4 Final Tier 3 Tier 3 Tier 4i
Displacement  cm³ 4,500 6,800 6,800 6,700
Operating performance ISO 3046 kW 154     191
Operating performance SAE J1995, ISO 8528-1 kW   147 147  
at rpm  rpm 1,800 1,800 1,800 1,800
Coolant Capacity l 43 28.8 28.8 29.3
Engine oil Capacity l 14.5 32.5 32.5 17.5
Fuel type  #1/#2 ULSD Diesel Diesel Diesel
Fuel consumption (Prime Load) l/h 32 33.5 33.5 34
Tank capacity - Fuel l 710 1,104 1,104 1,104
Quantity (Battery) 2 1 1 2
Battery  V 12 12 12 12
Generator model  Mecc Alte, Brushless w/AVR Mecc Alte, Brushless w/AVR Mecc Alte, Brushless w/AVR Mecc Alte, Brushless w/AVR
Voltage control No Load to Full Load +/- % 1 1 1 1
Voltage control Steady State +/- % 0.2 0.2 0.2 0.2
Generator insulation (class)  H H H H
Frequency (Generator Speed) Hz 60 60 60 60
Runtime at 100% Prime Load h 20.4 30.4 30.4 30
Runtime at 75% Prime Load h 27.1 38 38 38.1
Runtime at 50% Prime Load h 38.9 50.9 50.9 51.7
Runtime at 25% Prime Load h 64.5 96.9 96.9 78.6
Exhaust after treatment  AUS 32      
DEF Consumption  l/h 1.45      
Runtime DEF @ 100% Prime Load h 21.4      

Imperial

  G150 (T4F) G150 (T3) - Canada Only G150 (T3) 600V- Canada Only G150 (T4i) - Canada Only

Dimensions 

L x W x H Operating (Skid) in 110 x 45 x 66.3 132 x 52 x 68 132 x 52 x 68 132 x 52 x 70.5
L x W x H Shipping (Skid) in 113 x 47.5 x 78.4 135.5 x 54.5 x 81.5 135.5 x 54.5 x 81.5 135.5 x 54.5 x 84
L x W x H Shipping/Operating (Trailer) in 176 x 80 x 91.8 199 x 84.5 x 99 199 x 84.5 x 99 199 x 84.5 x 100.5

Weights 

Weight Dry (Skid) lb 5,300 6,202 6,304 6,143
Weight Operating (Skid) lb 6,400 8,302 8,404 8,243
Weight Shipping (Skid) lb 5,487 6,569 6,671 6,510
Weight Operating (Trailer) lb 7,770 9,782 9,884 9,723
Weight Shipping (Trailer) lb 6,670 7,682 7,784 7,623

Operating data 

Trailer coupling Type Pintle Pintle Pintle Pintle
Standby output   kW 130 133 130 133
Prime output  kW 121 121 118 121
Voltage - AC 3 Phase V 240/480 240/480 240/480/600 240/480
Current - 3 Phase (Prime) A 364/182 364/182 355/178/142 364/182
Current - AC 1 Phase A 120/240 120/240 120/240 120/240
Voltage - 3 Phase V 208, 220, 240, 416, 440, 480 208, 220, 240, 416, 440, 480 208, 220, 240, 416, 440, 480, 600 208, 220, 240, 416, 440, 480
Voltage - 1 Phase V 120, 127, 139, 240, 254, 277 120, 127, 139, 240, 254, 277 120, 127, 139, 240, 254, 277, 346 120, 127, 139, 240, 254, 277
Circuit breaker (Main) A 400 400 700 400
Frequency  Hz 60 60 60 60
Power factor 1 Phase cos Φ 1~ 1 1 1 1
Power factor 3 Phase cos Φ 3~ 0.8 0.8 0.8 0.8
Sound level (LwA) at Prime (23 ft / 7 m) dB(A) 73 67.5 67.5 70.4
Receptacles -20 Amp GFI Duplex 2 2 2 2
Receptacles -50 Amp Twist Lock 3 3 3 3

Engine / Motor 

Engine / Motor  Liquid-Cooled, 4 Cylinders Liquid-Cooled, 6 Cylinders Liquid-Cooled, 6 Cylinders Liquid-Cooled, 6 Cylinders
Engine / Motor manufacturer  Cummins QSB5-G12 John Deere John Deere Cummins
Emissions Certified Tier 4 Final Tier 3 Tier 3 Tier 4i
Displacement  in³ 275 415 415 409
Operating performance ISO 3046 hp 206     256
Operating performance SAE J1995, ISO 8528-1 hp   197 197  
at rpm  rpm 1,800 1,800 1,800 1,800
Coolant Capacity US qt 45 30.4 30.4 31
Engine oil Capacity US qt 15.3 34.3 34.3 18.5
Fuel type  #1/#2 ULSD Diesel Diesel Diesel
Fuel consumption (Prime Load) US gal/h 8.5 8.85 8.85 9
Tank capacity - Fuel US gal 187.6 291.7 291.7 291.7
Quantity (Battery) 2 1 1 2
Battery  V 12 12 12 12
Generator model  Mecc Alte, Brushless w/AVR Mecc Alte, Brushless w/AVR Mecc Alte, Brushless w/AVR Mecc Alte, Brushless w/AVR
Voltage control No Load to Full Load +/- % 1 1 1 1
Voltage control Steady State +/- % 0.2 0.2 0.2 0.2
Generator insulation (class)  H H H H
Frequency (Generator Speed) Hz 60 60 60 60
Runtime at 100% Prime Load h 20.4 30.4 30.4 30
Runtime at 75% Prime Load h 27.1 38 38 38.1
Runtime at 50% Prime Load h 38.9 50.9 50.9 51.7
Runtime at 25% Prime Load h 64.5 96.9 96.9 78.6
Exhaust after treatment  AUS 32      
DEF Consumption  US gal/h 0.38      
Runtime DEF @ 100% Prime Load h 21.4